PA66 ST801 NC010A 超韧尼龙,高生产率
Zytel® ST801 NC010A | PA66-I
Regional Availability
Europe, Near East/Africa
Processing
Injection Moulding, Other Extrusion
Product Text
Common features of Zytel® nylon resin include mechanical and physical properties such as high mechanical strength, excellent balance of stiffness and toughness, good high temperature performance, good electrical and flammability properties, good abrasion and chemical resistance. In addition, Zytel® nylon resins are available in different modified and reinforced grades to create a wide range of products with tailored properties for specific processes and end-uses. Zytel® nylon resin, including most flame retardant grades, offer the ability to be coloured.
The good melt stability of Zytel® nylon resin normally enables the recycling of properly handled production waste. If recycling is not possible, DuPont recommends, as the preferred option, incineration with energy recovery (-31kJ/g of base polymer) in appropriately equipped installations. For disposal, local regulations have to be observed.
Zytel® nylon resin typically is used in demanding applications in the automotive, furniture, domestic appliances, sporting goods and construction industry.
Zytel® ST801 NC010A is an unreinforced, super tough polyamide 66 for injection molding and extrusion. It offers outstanding impact resistance over a wide temperature and humidity range and high productivity.
PROPERTIES
Rheological properties | dry / cond | Unit | Test Standard |
Moulding shrinkage,parallel | 1.7 / * | % | ISO 294-4,2577 |
Mechanical properties | dry / cond | Unit | Test Standard |
Tensile Modulus | 2000 / 900 | MPa | ISO 527-1/-2 |
Yield stress | 50 / 43 | MPa | ISO 527-1/-2 |
Yield strain | 5.7 / 37 | % | ISO 527-1/-2 |
Nominal strain at break | 32 / >50 | % | ISO 527-1/-2 |
Stress at 50% strain | * / 39 | MPa | ISO 527-1/-2 |
Tensile creep modulus,1h | * / 1200 | MPa | ISO 899-1 |
Tensile creep modulus,1000h | * / 750 | MPa | ISO 899-1 |
Charpy impact strength,23℃ | N / N | kJ/m² | ISO 179/1eU |
Charpy impact strength,-30℃ | N / N | kJ/m² | ISO 179/1eU |
Charpy notched impact strength,23℃ | 80 / 115 | kJ/m² | ISO 179/1eA |
Charpy notched impact strength,-30℃ | 18 / 17 | kJ/m² | ISO 179/1eA |
Thermal properties | dry / cond | Unit | Test Standard |
Melting temperature,10℃/min | 263 / * | ℃ | ISO 11357-1/-3 |
Glass transition temperature,10℃/min | 75 / - | ℃ | ISO 11357-1/-2 |
Temp. of deflection under load,1.8 MPa | 64 / * | ℃ | ISO 75-1/-2 |
Temp. of deflection under load,0.45 MPa | 132 / * | ℃ | ISO 75-1/-2 |
Coeff. of linear therm. expansion,parallel | 120 / * | E-6/K | ISO 11359-1/-2 |
Coeff. of linear therm. expansion,normal | 90 / * | E-6/K | ISO 11359-1/-2 |
Flammability | dry / cond | Unit | Test Standard |
Burning Behav. at 1.5 mm nom. thickn. | HB / * | class | IEC 60695-11-10 |
Thickness tested | 1.5 / * | mm | IEC 60695-11-10 |
Burning Behav. at thickness h | HB / * | class | IEC 60695-11-10 |
Thickness tested | 0.8 / * | mm | IEC 60695-11-10 |
Oxygen index | 20 / * | % | ISO 4589-1/-2 |
Glow Wire Flammability Index,0.75mm | 725 / - | ℃ | IEC 60695-2-1/2 |
Glow Wire Flammability Index,1.5mm | 675 / - | ℃ | IEC 60695-2-1/2 |
Glow Wire Flammability Index,3mm | 650 / - | ℃ | IEC 60695-2-1/2 |
Glow Wire Ignition Temperature,0.75mm | 675 / - | ℃ | IEC 60695-2-1/3 |
Glow Wire Ignition Temperature,1.5mm | 675 / - | ℃ | IEC 60695-2-1/3 |
Glow Wire Ignition Temperature,3mm | 675 / - | ℃ | IEC 60695-2-1/3 |
Electrical properties | dry / cond | Unit | Test Standard |
Relative permittivity,100Hz | 3.2 / 8 | - | IEC 60250 |
Relative permittivity,1MHz | 2.9 / 3.6 | - | IEC 60250 |
Dissipation factor,100Hz | 80 / 1800 | E-4 | IEC 60250 |
Dissipation factor,1MHz | 140 / 550 | E-4 | IEC 60250 |
Volume resistivity | 1E13 / 1E11 | Ohm*m | IEC 60093 |
Surface resistivity | * / >1E15 | Ohm | IEC 60093 |
Electric strength | 31 / 39 | kV/mm | IEC 60243-1 |
Comparative tracking index | 600 / - | - | IEC 60112 |
Other properties | dry / cond | Unit | Test Standard |
Water absorption,2mm | 6.7 / * | % | Sim. to ISO 62 |
Humidity absorption,2mm | 2.2 / * | % | Sim. to ISO 62 |
Density | 1080 / - | kg/m³ | ISO 1183 |
VDA Properties | Value | Unit | Test Standard |
Burning rate,Thickness 1 mm | 26 | mm/min | ISO 3795 (FMVSS 302) |
Emission of organic compounds | 38.4 | µgC/g | VDA 277 |
Odour | 3 | class | VDA 270 |
Chemical Media Resistance
Acids
√ Acetic Acid (5% by mass) (23℃)
√ Citric Acid solution (10% by mass) (23℃)
√ Lactic Acid (10% by mass) (23℃)
× Hydrochloric Acid (36% by mass) (23℃)
× Nitric Acid (40% by mass) (23℃)
× Sulfuric Acid (38% by mass) (23℃)
× Sulfuric Acid (5% by mass) (23℃)
× Chromic Acid solution (40% by mass) (23℃)
Bases
× Sodium Hydroxide solution (35% by mass) (23℃)
√ Sodium Hydroxide solution (1% by mass) (23℃)
√ Ammonium Hydroxide solution (10% by mass) (23℃)
Alcohols
√ Isopropyl alcohol (23℃)
√ Methanol (23℃)
√ Ethanol (23℃)
Hydrocarbons
√ n-Hexane (23℃)
√ Toluene (23℃)
√ iso-Octane (23℃)
Ketones
√ Acetone (23℃)
Ethers
√ Diethyl ether (23℃)
Mineral oils
√ SAE 10W40 multigrade motor oil (23℃)
× SAE 10W40 multigrade motor oil (130℃)
× SAE 80/90 hypoid-gear oil (130℃)
√ Insulating Oil (23℃)
Standard Fuels
√ ISO 1817 Liquid 1 (60℃)
√ ISO 1817 Liquid 2 (60℃)
√ ISO 1817 Liquid 3 (60℃)
√ ISO 1817 Liquid 4 (60℃)
√ Standard fuel without alcohol (pref. ISO 1817 Liquid C) (23℃)
√ Standard fuel with alcohol (pref. ISO 1817 Liquid 4) (23℃)
√ Diesel fuel (pref. ISO 1817 Liquid F) (23℃)
× Diesel fuel (pref. ISO 1817 Liquid F) (90℃)
× Diesel fuel (pref. ISO 1817 Liquid F) (>90℃)
Salt solutions
√ Sodium Chloride solution (10% by mass) (23℃)
× Sodium Hypochlorite solution (10% by mass) (23℃)
√ Sodium Carbonate solution (20% by mass) (23℃)
√ Sodium Carbonate solution (2% by mass) (23℃)
× Zinc Chloride solution (50% by mass) (23℃)
Other
√ Ethyl Acetate (23℃)
× Hydrogen peroxide (23℃)
× DOT No. 4 Brake fluid (130℃)
× Ethylene Glycol (50% by mass) in water (108℃)
√ 1% nonylphenoxy-polyethyleneoxy ethanol in water (23℃)
√ 50% Oleic acid + 50% Olive Oil (23℃)
√ Water (23℃)
× Water (90℃)
× Phenol solution (5% by mass) (23℃)
Symbols used:
√ possibly resistant
Defined as: Supplier has sufficient indication that contact with chemical can be potentially accepted under the intended use conditions and expected service life. Criteria for assessment have to be indicated (e.g. surface aspect, volume change, property change).
× not recommended - see explanation
Defined as: Not recommended for general use. However, short-term exposure under certain restricted conditions could be acceptable (e.g. fast cleaning with thorough rinsing, spills, wiping, vapor exposure).