Product Description
Ultrasonicembedded flowmeterflowmeter is a high-precision measurement using ultrasonic Venturi or Parshall flume drainage flow meter, which measures the sound waves in the water after exposure to the channel reflected back time, and then according to the formula to calculate the flow channel, it can providing a flow rate output, display the flow rate and total flow.
Application
Water and wastewater treatment
Pumping stations, collection wells, biochemical reaction tanks, sedimentation tanks, etc.
Electricity, mining
Mortar pool, coal slurry pond, butter tanks, stockyard or part of the mobile device control, etc.
Food Industry
Wineries, granary, food material containing tanks and other equipment
supporting the use of the control system
Feature
Flow Totalizer parameters
Flow measuring range: 0 ~ 93m3 / s (and identified with the weir trough range with the relevant specifications)
Suitable weir trough type: triangular weir, rectangular weir, and other wide weir, Parshall flume
Display accuracy: Depending on the input signal
And with the amount of water flow error related weir trough
Equipped with a triangular weir: 1 to 2 percent with a rectangular weir: 1 to 4 percent equipped with Parshall slots: 3%
Calibration: Factory calibrated, field calibration
Display: 2.8 inches Chinese LCD
Display screen: liquid level, flow rate, total flow, flow rate, daily flow, weekly traffic, monthly traffic, date, battery level (can be set)
Signal Input: 4 ~ 20mA; 0 ~ 20mA; 1 ~ 5V; 0 ~ 5V; RS485;
Key: 4 touch keys
Output
Voltage Output: DC 12V or 24V
Signal output: RS485 / RS232; 4 ~ 20mA; 3-channel relay
Relay contact capacity: AC: 5A 120V DC: 10A 24V
Powered by
Working voltage: DC24V or AC160V ~ 250V normal power: <5W
Physical properties
Host Dimension: 240 * 184 * 110MM
Shell Material: ABS plastic; transducer: PP
Connection: threaded connection or spiro fixed
Installation: thread M48 × 1.5
Keyboard: five SMD keys
Sensor cable: 10M (optional arbitrary length)
Environmental performance
Operating temperature: 0 ~ 50 centigrade ambient humidity: ≤85RH pressure: atmospheric pressure
Data Storage
Over the past 168 hours traffic flow over the past 31 days
Over the past 14 weeks Flow
Over the past 36 months traffic
Over the past decade traffic
Optional Equipment
Mini printer 12V battery
Level gauge wire: connect the farthest 1,000 meters, with user-
Minimum display resolution: 1MM
Temperature compensation: Automatic temperature compensation
Operating frequency: 20 KHz ~ 200KHz (due to different model specifications)
Setting the scene: the key to complete by the machine
Calibration: Factory calibrated, field calibration
Display: 3-inch LCD Chinese
Support for data collection