Preheating |
Preheating zone quan. | Preheating length is 1800mm, divided into 4 sections, supply abundant adjusting space, very good for big PCB and complicated PCB. Reduce the heat impact on PCB, improve the production efficiency. |
Temp. control method | Mitsubishi temp. collecting module, PID is very precise and stable. |
Heating parts | The heaters are imported from Taiwan, heat up very fast, with long life, small thermo lag; The heat is even in the zones. |
Preheating power | 22kw |
Install mode | The heating module adopts drawer design, easy to replace and repair, make the maintenance very convenient. |
Transmission |
Rail | Made of aluminum, wear resistant and without distortion. |
Rail parallelism | Width adjusting accuracy less than 0.2mm |
Width adjust | Manually/motorized |
C/V speed setting unit | Min.1mm/min 0-1800mm/min |
C/V speed variation range | Electric closed-loop control, within 0-10mm/min |
Conveying motor | TCG motor from Taiwan,90w, with over-loaded protection function. |
Solder pot |
Low oxidization design | High quality solder pot, the heat is very steady. Adopts liquid solder flow design, reduce the impact oxidization, especially for small PCB. |
Economical running | Reduce the power consumption |
Moving method | Motorized |
Wave adjustable height | 0-18mm |
Wave motor | TCG motor from Taiwan,adjust the wave height with frequency conversion. |
Preheating parts | Adopts the stainless steel heaters from Taiwan, with long life and power saving up to 40% daily. |
Cooling |
Cooling method | Adopts high power centrifugal fan, reduce the air bubble and solder pad stripping |
Automatic finger cleaning |
Imported premium pump, can wash the fingers from both side. Propyl alcohol to clean and can be recycled. |
Control software |
★Automatic alarm function for failure::thermocouple abnormal,temp. too high or too low;if preheating system or solder pot is abnormal, the heating stops. |
★Preheating temp., solder pot temp., conveyor speed, spraying and cooling can be controlled separately. |
★One week automatic power on/off setting (three times one day) |
★The emergency stops are in front, rear of the machine, press them in case of any emergency. |
| | |