lithium battery Of BMS for electric bike

名称:lithium battery Of BMS for electric bike

供应商:锂源电池有限公司

价格:面议

最小起订量:0/

地址:河北省唐山市曹妃甸工业工业区装备制造产业园区

手机:18814365575

联系人:王小姐 (请说在中科商务网上看到)

产品编号:60839606

更新时间:2018-05-25

发布者IP:59.39.132.186

详细说明

  The main function of Remarks

  A battery voltage detection : For 10 amp battery using principal differential detection from transportation, to ensure accuracy , precision voltage detection voltage detection control system within ± 15mV.

  Temperature detection : with a negative temperature coefficient NTC temperature sensor detects the temperature , the temperature detection range -20 ℃ to 80 ℃, can be a point or two-point temperature , temperature detection accuracy of ± 2 ℃

  3 Current detection : current detection precisely calibrated accuracy up to ± 300mA.

  4 power measurement : electricity metering points can be used to measure voltage and current measurements . Optional

  5 communication ports : Connect to the PC host computer for data monitoring, acquisition and calibration procedures . Only for testing

  6.LED instructions : BMS optional LED indicates battery voltage , battery charge and discharge , and failure status . Optional

  7 system self-test :. BMS system set up self-test function , the system power voltage , temperature, communications and other components for testing to ensure that the system itself is working properly.

  8 System Monitoring :. BMS for the battery pack voltage, current and temperature monitoring , the effective protection of the battery pack when a failure occurs .

  9 discharge activation : BMS activation charge a load or , in the case do not take the load and the charger , BMS in the off state , BMS at this time is almost zero power state, then load or charger when BMS activated automatically enter the working state . BMS after activation , if the load within one hour or the charger is not connected , BMS automatically enters power-down state .

  10.BMS with internal discharge absorb the counter electromotive force protection .

  11 charge-discharge circuit: can be charged and discharged the same port , or charging , discharging port separation.

  Billion to Electronic Co., Ltd. . Standard file EPOWER ELECTRONIC CO., LTD. Standard Document

  File Name Document name version Revision Page Page

  Document Number Document NO. Controlled number Controled implementation date Issued date

  3 , the technical parameters :

  Electric Parameter:

  Item Item temperature 25 ℃ Normal Temperature 25 ℃

  Min (Min) normal (Type) max (Max) Note )

  Overcharge detection voltage (V) 3.785 3.800 3.815 adjusted according to customer requirements

  Overcharge protection delay time (mS) 1900 2000 2100 adjusted according to customer requirements

  Overcharge recovery voltage (V) 3.585 3.600 3.615 adjusted according to customer requirements

  Over-discharge protection voltage (V) 2.385 2.400 2.415 adjusted according to customer requirements

  Over-discharge protection delay time (ms) 1900 2000 2100 adjusted according to customer requirements

  Over-discharge recovery voltage (V) 2.585 2.600 2.615 adjusted according to customer requirements

  Charge current protection (A) 39A 40A 41A adjusted according to customer requirements

  Discharge overcurrent protection current (A) 119A 120.0 121A adjusted according to customer requirements

  Discharge overcurrent Delay (ms) 400 500 600 adjusted according to customer requirements

  Discharge overcurrent way to lift a load lifted off

  BMS static self- consumption ( off load ) (uA) ≤ 30uA

  On- resistance (mΩ) ≤ 10mΩ

  Short circuit protection current > 200A adjustable

  Short circuit protection to lift the load lifted off mode

  Continuous discharge current of 30A adjustable

  BMS consumable ( connected to the load or charger ) ≤ 15mA

  Equalization in the charged state , when the voltage is greater than the lowest cell voltage 2.8V, and if other batteries and cell voltage is greater than the difference between the minimum 25mV, then open the corresponding batteries equalization , equalization current 56 ~ 82mA ( depending turn-on voltage of batteries equilibrium may be) , the voltage difference between the close balance is less than 25mV. Discharged state without opening equalization. Adjusted according to customer requirements

  Charging temperature protection ℃ 43 45 47 Adjustment upon request

  Charging high temperature protection and restoration (℃) 38 40 42

  Charging low temperature protection (℃) -2 0 2

  Discharge temperature protection (℃) 58 60 62

  Discharge temperature protection and restoration (℃) 58 60 62

  Low discharge protection (℃) -18 -20 -22

  Low discharge protection and restoration (℃) -2 0 2

  Operating temperature range -20 ℃ to 70 ℃

  Maximum operating humidity 90%

  Protection plate size (mm × mm × mm) 136 × 65 × 12 ( height with heatsink )