| project | technical Specifications |
| software | Independent research and development,Scalability,Compatible EZFIX,CAM350 and other commonly used engineering processing software. |
| operator Interface | the WINDOWSXP all-english operating system |
| maximum discharge board area | 620 mm×510 mm |
| maximum test area | 610 mm×510 mm |
| plate thickness | 0.5mm–5. 5mm( optional) |
| enter | Gerber,DPF,IPC356,Probotformat |
| test voltage | 25V–220V |
| test current | 30mA–200mA |
| insulation test | 5MΩ–249MΩ |
| conduction test | 2Ω–1000Ω |
| minimum pad size | 0.004″(100um) |
| minimum pad pitch | 0.010″(254um) |
| X / Y axis resolution | 0.002″(50.8um) |
| X / Y axis precision | 0.001″(25.4um) |
| dynamic repeatability | (+/- 0.001″ 25.4um ) |
| touch screen control | optional (nonstandard configuration) |
| X / Y axis positioning | automatic |
| rotation compensation | automatic |
| suspend recovery adjustment | automatic |
| positioning the needle positioning | automatic,mechanical find something |
| number of fly thorium probe | 2 front2 after |
| flying needlepoint | 0.003″×0.003″(76.2×76.2um) |
| flying pressure | 20–40gadjustable |
| X / Y axis | high-precision soft belt drive |
| Z-axis | high-precision soft belt drive |
| Z-axis frequency | 4–20Hz |
| power | 220V, 50/60Hz, 500W |
| environment | 19–23℃;50–65% relative temperature |
| size | long:1490mm,wide: 650mm,high: 1750mm |
| weight | 450kilogram (with accessories) |