N4L PPA5500多功能高精度功率分析仪

名称:N4L PPA5500多功能高精度功率分析仪

供应商:深圳市全亿达电子有限公司

价格:1.00元/台

最小起订量:1/台

地址:广东省深圳市南山区桂庙路62号顺天大厦5A

手机:13922871080

联系人:杨聪 (请说在中科商务网上看到)

产品编号:52557071

更新时间:2024-12-18

发布者IP:111.85.9.32

详细说明

  PPA5500多功能高精度功率分析仪

  Leading wideband accuracy Basic 0.01% with class leading high frequency performance

  Wide frequency range DC, 10mHz to 2MHz - PPA5500 / DC, 10mHz to 1MHz - PPA1500 / DC, 10mHz to 500kHz - PPA500Fast sample rate and No-Gap 2.2M samples/s - PPA5500 / 1M samples/s - PPA1500/500, High accuracy in noisy applicationsLeading phase accuracy 0.005 Degrees plus 0.01 degrees per kHzBuilt in high precision current shunt 10Arms, 30Arms or 50Arms with up to 1000Apk direct plus a wide range of external sensorsVersatile interfaces RS232, USB, LAN, GPIB (PPA5500) plus direct torque and speed (PPA5500)Range of PC software options Remote control, monitoring and recording of real time data, tables and graphs PPA500Series

  Leading wideband accuracy Basic 0.01% with class leading high frequency performance

  ① FRONT USB PORTUSB memory port allows data or screendumps to be saved directly to a USB pen drive② POWER BUTTON③ DISPLAY SCREENWhite LED backlight colour TFT display with high contrast and wide viewing angle④ SCREEN DISPLAY OPTIONSZoom, Real time, Table and Graph options⑤ MEASUREMENT FUNCTION SELECTION BUTTONS

  ⑨PHASE INPUTS

  Direct voltage Input: 3kVpk (1kVrms) in 9 ranges

  Direct current Input: 300Apk (30Arms) Standard Model, 30Apk (10Arms) Low Current Model, 1000Apk (50Arms) High Current Model

  External voltage and current sensor inputs to 3Vpk in 9 ranges - BNC Connector

  PPA1500/500: 300Apk (20Arms) direct current input, PPA1500/500-HC: 1000Apk (30Arms)

  ⑩SYNC CONNECTOR

  All PPA models can offer up to 9 phase analysis using the PPALoG PC program Additionally two PPA5530's can be connected via the extension port and sync BNC connector to form a 6 phase analyzer when a PC is not available (PPA5500 only)

  ⑪EXTERNAL SENSOR INPUTS

  +/-10V or pulsed input from torque and speed sensors provides direct measurement of mechanical power + Analogue output (PPA5500 only)

  ⑫PC INTERFACE CONNECTIONS

  Standard interfaces RS232 + USB + LAN (Optional) + GPIB (Optional on PPA5500 only)

  ⑬LOW NOISE EFFICIENT FANS

  Air bearing low noise fans are utilized to ensure minimum audible and electrical noise while maintaining a stable operating temperature for the high precision low inductance internal current shunts

  Frequency Range

  DC,10mHz~2MHz - PPA5500-LC(10Arms), PPA5500(30Arms)DC,10mHz~1MHz - PPA5500-HC(50Arms)

  300mVpk~3000Vpk(1000Vrms) in 9 ranges(240Vrms within 300Vpk range, using 20% overange)

  0.01% Rdg+0.038% Rng+(0.004%×kHz)+1mV

  300µVpk~3Vpk in 9 ranges 【BNC connector 3Vpk max input】

  0.01%Rdg+0.038%Rng+(0.004%×kHz)+1µV