Model | TR668/TR668R | TR668A/TR668R |
| CC/CR/CV/CP | CC/CR/CV/CP |
Ratings | | |
Voltage | 60V | 300V |
Current | 60A | 10A |
Power | 300W | 300W |
Min Operating Start Voltage | 1.5V | 1.5V |
Constant Cuttent Mode | | |
Range | High/low:0-60A | High/low:1-10A |
Accuracy | 0.3%+3counts | 0.3%+3counts |
Resolution | High/Low:1mA | High/Low:1mA |
Constant Resistance Mode | | |
Range | High/Low:0.05Ω-4kΩ | High/Low:0.5Ω-9.999kΩ |
Accuracy | 1% | 1% |
Resolution | High/Low:1mΩ | High/Low:1mΩ |
Constant Vltage Mode | | |
Range | 0-60V | 0-300V |
Accuracy | 0.5% | 0.5% |
Resolution | 1mV | 1mV |
Constant Power Mode | | |
Range | 0-300W | 0-300W |
Accuracy | 0.5% | 0.5% |
Resolution | 1mW | 1mW |
Dynamic Operation | | |
Dynamic Mode | CC Mode | CCMode |
Setting Time | High/Low:20us-9999sec | High/Low:20us-9999sec |
Slew Rate | High/Low:1mA-2.5A/us | High/Low:1mA-9.999A/us |
Accuracy | 5% | 5% |
Voltage Read Back | | |
Accuracy | 0.1%+10mV | 0.1%+10mV |
Resolution | High:0.01V Low:0.001V | High:0.1V Low:0.01V |
Current Read Back | | |
Accuracy | 0.3%+20mA | 0.3%+20mA |
Resolution | High:0.01A Low:0.001A | High:0.01A Low:0.001A |
Current monitor | | |
Full Scale Output Voltage | 10V/60A | 10V/10A |
Accuracy | 2%+100mV | 2%+100mA |
Function | Built-in with short current indicate | |
Memory | 40set test parameter store,recall function |
General | | |
Operation Environment | Temeperature:0-40℃ Humidity:≤80%RH |
Power Consumption | 100W max |
Power Requirement | 100V/120V/220V/240V |
Frequency | 50/60Hz |
Weight | TR668R/TR668AR:29kg TR668/TR668A:7kg |
Dimension(W×H×D) | TR668R/TR668AR:430×177×440mm TR668/tr668A:177×110×440mm |