Description |
Sensor type | integrated circuit temperature sensor with six plate radiation shield |
| |
Applications | wind resource assessment |
meteorological studies |
environmental monitoring |
| |
Sensor range | -40 °C to 52.5 °C (-40 °F to 126.5 °F) |
| |
Instrument compatibility | all NRG loggers |
| |
Output signal |
Signal type | linear analog voltage |
| |
Transfer function | Temp = (Voltage x 55.55) - 86.38 °C |
[Temp = (Voltage x 100) - 123.5 °F] |
| |
Accuracy | offset is +/- 0.8 °C (1.4 °F) maximum |
nonlinearity is +/- 0.33 °C (+/- 0.6 °F) maximum |
total error +/- 1.1 °C (2 °F) maximum |
| |
Electrical time constant | 250 µs |
| |
Output signal range | 0 V to 2.5 V DC |
| |
Response characteristics |
Thermal time constant | 10 minutes |
| |
Power requirements |
Supply voltage | 4 V to 35 V DC |
| |
Supply current | 300 µA max. (no load on output) |
| |
Installation |
Mounting | attaches to tower with included hose clamps |
| |
Tools required | 8mm (5/16 inch) nut driver or flat blade (-) screwdriver (to install hose clamps) |
sheet metal shears or similar (for trimming hose clamps) |
| |
Environmental |
Operating temperature range | -40 °C to 52.5 °C (-40 °F to 126.5 °F) |
| |
Operating humidity range | 0 to 100% RH |
| |
Lifespan | 10 years + |
| |
Physical |
Connections | wire leads: |
signal (clear wire) |
ground (black wire) |
excitation (red wire) |
shield wire for earth ground |
| |
Cable length | 5 m (16 feet) |
| |
Weight | 0.47 kg (1.04 pounds) |
| |
Dimensions | sensor only: 30.5 mm (1.2 inches) height x 12.7 mm (0.5 inch) diameter |
sensor with radiation shield: 127 mm (5 inches) diameter x 127 mm (5 inches) height |
| |
Materials |
Cable | 3 conductor 22 AWG, with overall foil shield and drain wire, chrome PVC jacket |
| |
Probe | aluminum, epoxy filled |
| |
Shield | UV-stabilized thermoplastic solar radiation shield |