时间:2017-04-04 20:55
上海湘赛自动化设备有限公司
EL2502 | 2-channel pulse width output terminal 24 V DC
The EL2502 output terminal modulates the pulse width of a binary signal and outputs it electrically isolated from the E-bus. The mark/space ratio is prescribed by a 16 bit value from the automation unit. The output stage is protected against overload and short-circuit. The EtherCAT Terminal has two channels that indicate their signal state via LEDs. The LEDs are driven in time with the outputs, and show the mark/space ratio by their brightness.
| Technical data | EL2502 | ES2502 |
|---|
| Connection technology | PWM output, push-pull outputs |
| Number of outputs | 2 |
| Rated load voltage | 24 V DC (-15 %/+20 %) |
| Load type | ohmic, inductive, lamp load |
| Distributed clocks | – |
| Max. output current | 0.5 A (short-circuit-proof) per channel |
| Short circuit current | typ. < 1.5 A |
| PWM clock frequency | 20 Hz…20 kHz, 250 Hz default |
| Base frequency | 1 Hz…125 kHz, 250 Hz default |
| Duty factor | 0…100 % (TON > 750 ns, TOFF > 500 ns) |
| Resolution | 9…15 bit |
| Reverse voltage protection | yes |
| Current consumption E-bus | typ. 150 mA |
| Electrical isolation | 500 V (E-bus/field potential) |
| Current consumption power contacts | typ. 30 mA + load |
| Bit width in the process image | 2 x 16 bit PWM output |
| Configuration | via TwinCAT System Manager |
| Special features | separate frequency can be set for each channel |
| Weight | approx. 50 g |
| Operating/storage temperature | 0…+55 °C/-25…+85 °C |
| Relative humidity | 95 %, no condensation |
| Vibration/shock resistance | conforms to EN 60068-2-6/EN 60068-2-27 |
| EMC immunity/emission | conforms to EN 61000-6-2/EN 61000-6-4 |
| Protect. class/installation pos. | IP 20/variable |
| Pluggable wiring | for all ESxxxx terminals |
| Approvals | CE, UL, Ex |