详细说明
Specification Sheet |
Model Specification | LST-1210-9-CP |
Output Specification | Output Voltage | (Voltage adjustable:±10%rated output voltage) |
Rated Current | 10A |
Output Channels | 9 |
Single Channel Current Range | 0---1.1A |
Ripple Wave | |
Output Accuracy | ±5% |
Line Regulation | ±2% |
Load Regulation | ±5% |
Rated Power | 120W |
Single Channel Output Power | 13.3W |
Output Startup time | ≤2S@120VAC≤1.0S@230VAC |
Output holding time | ≥10mS@120VAC,≥20mS@230VAC |
Input | Input voltage range | 90V---265V AC |
Normal Operating Voltage Range | 100V---240V AC |
Input Current | 2A/110V; 1A/220V; |
Frequency Range | 47---63Hz |
Efficiency | ≥85% |
Protection
Over-load protection
105%-150%Rated power, auto recovery
Output over-voltage protection
110%-120%Rated voltage
Output short-circuit protection
When short-current occurs, the power supply will automatically switch to self-protection status. When condition removed, then switch back to normal.
Over-temperature protection
/
Other functions
Environmental Features
Working temperature & humidity
-20~+40℃@100%LOAD, +60℃@60%LOAD, 20%~90%RH
Storage Temperature & Humidity
-20~+85℃ , 10%~95%RH
Cooling Way
Auto
Safety & EMC
Safety Standard
EN/UL60950
Design reference EN/UL60950
EMC Standards
EN55022 Class B;
Design reference EN55022 Class B;
High-voltage
Holding Test
I/P-O/P: 3KV AC, 10mA,60S
Insulation Resistance
I/P-O/P: 500VAC 100MΩ
Shape & Weight
Weight
1000±10g
Dimensions
L255*W208*H90mm
Remark
1, All the data is recorded by the test with Input 220VAC, rating load, 25 Degree working temperature, 70% Humidity.
2, Precision include setting error, Line change rate, load change rate, etc.
3, Ripple Wave Test: Use 30cm cable t