详细说明
| Specification Sheet |
| ModelSpecification | HP-A1205-4-CP |
| Output Specification | output voltage | DC 12V |
| Rated Current | 5A |
| Output Channels | 4 |
| Single Channel Current Range | 0---1.25A |
| Ripple Wave | <120mVp-p |
| Output Accuracy | ±5% |
| Line Regulation | ±2% |
| Load Regulation | ±2% |
| Rated Power | 60W |
| Single Output Power | 15W |
| Input Specification | Input Voltage Range | 90V---265V AC |
| Normal Operating voltage Range | 100V---240V AC |
| Input Current | 0.9A/110V; 0.6A/220V; |
| Frequency Range | 47---63Hz |
| Efficiency | ≥85% |
Protection Features
Over-load protection
105%-150%Rating Power, auto recovery
Over-voltage protection
110%-130% Rated Voltage
Output short-circuit protection
When short-current occurs, the power supply will automatically switch to self-protection status. When condition removed, then switch back to normal.
Over-temperature protection
/
Other Functions
Environmental Features
Working temperature & humidity
-20~+40℃@100%LOAD, +60℃@60%LOAD, 20%~90%RH
Storage temperature & humidity
-20~+85℃ , 10%~95%RH
Cooling Way
Auto
Safety and EMC standard
Safety Standard
EN/UL60950
EMC Standards
EN55022 Class B;
High-voltage
HoldingTest
I/P-O/P: 2KV AC, 10mA,60S
Insulation Resistance
I/P-O/P: 500VAC 100MΩ
Reliability
MTBF
MIL-HDBK-217F standard, full-loaded, 25℃, more than 30000h
Shape & Weight
Weight
230±10g
Dimensions
166mm*55mm*34.5mm
Remark
1, All the data is recorded by the test with Input 220VAC, rating load, 25 Degree working temperature, 70% Humidity.
2, Precision includes setting error, Line change rate, load change rate, etc.
3, Ripple Wave Test: Use 30cm cable to connect the power and the load