详细说明
Specification Sheet: |
ModelSpecification | HP-P150PDS |
Output Specification | output voltage | V1 52.5V | V2 12.0V |
Rated Current | 1.65A | 6A |
Current Range | 0---1.65A | 0---6A |
Ripple Wave | 300mVp-p | 150mVp-p |
Output Accuracy | ±2% | ±2% |
Line Regulation | ±1% | ±1% |
Load Regulation | ±1% | ±1% |
Rating Power | 150W |
Connect, recover and remain time | 500ms , 25ms, 40ms/220VAC |
Input Specification | Input Voltage Range | 90V---264V AC ; 120V---360V DC |
Input Current | 1.8A/110V; 1.0A/220V; |
Frequency Range | 47---63Hz |
Efficiency | ≥85% 100V |
PF data | 0.98/220VAC |
Impact Current | COLD START : 35A /230VAC |
LeakageCurrent | <3.5mA(AC input to the land) |
Protection Features
overload protection
105%-150% Rating Power, auto recovery
overvoltage protection
V1 : 50V-55V
V2: 13.5V-14.5V
Output short circuit protection
The power supply will not broken after long time output short-circuit, remove the short-circuit, the power can recover work.
Over temperature protection
Auto recover
Other Functions:
Environmental Features
Working Temperature, Humidity
-20~+50℃@100%LOAD, +60℃@60%LOAD, 20%~90%RH
Storage Temperature, Humidity
-20~+85℃ , 10%~95%RH
Temperature Range
±0.03%/℃(0-50℃)
Heating Way
Auto
Safety and EMC standard
Safety Standard
UL 60950-2003
High-voltageHoldingTest
I/P-O/P:3KV; I/P-FG:2.0KV; O/P-FG:500VAC 10mA,1Min
Insulation resistance
I/P-O/P; I/P-FG; O/P-FG:500VAC 100M
Other specification
Size
154mm*82mm*24mm
Weight