  Thermal (T- and TA-Line)

  Circuit Breakers

  Circuit Breaker for Equipment thermal, Threaded neck type, Reset type, Quick connect terminals

  Description

  - Threaded neck type 6 mm

  - Thermal circuit breaker

  - 1-pole

  - Reset type

  - Positively trip-free release

  - Quick connect terminals 6.3 x 0.8 mm

  Standards

  - VDE Certificate Number: IEC 60934

  - UL File Number: UL 1077

  - CSA File Number: CSA C22.2 235

  - GB Standard: GB 17701

  Applications

  - Power tools

  - Household Equipment

  - Power supplies and chargers

  - Industrial appliances

  Weblinks

  pdf-datasheet, html-datasheet, General Product Information, Approvals,

  CE declaration of conformity, RoHS, CHINA-RoHS, REACH, e-Shop,

  SCHURTER-Stock-Check, Distributor-Stock-Check, Detailed request for

  product, Product News

  Technical Data

  Rated Voltage AC 240 V; 50/60 Hz

  Rated Voltage DC 48 V

  Rated current range AC 0.05 - 16 A

  Conditional short circuit capacity

  IEC: Inc, PC1, AC 240 V: 2 kA

  Short circuit capacity Icn at In 1.5kV

  Impulse 1.2/50 μs: > 2.5kV

  Insulation resistance 500VDC > 100 MΩ

  Endurance typical 2 x Ir: 500switching cycles

  Endurance minimum Reset type

  AC : 2 x Ir , cos φ 0.6 :

  DC : 2 x Ir , L/R = 2 - 3 ms :

  50switching cycles

  Overload IEC: min. 40trips

  @ 6 x Ir, cos φ 0.6

  UL / CSA: min. 50trips

  @ 1.5 x Ir, cos φ 0.75

  Ambient temperature -5°C to 60°C

  Vibration Resistance ± 1.5 mm @ 10 - 60 Hz

  acc. to IEC 60068-2-6, test Fc

  5 G @ 60 - 500 Hz

  acc. to IEC 60068-2-6, test Fc

  Shock Resistance 100 G / 6ms

  acc. to IEC 60068-2-27, test Ea

  Tripping Type Thermal

  Actuation type Reset type

  Weight ca. 10g

  Effect of ambient temperature

  The units are calibrated for an ambient temperature of +23°C. To determine the rated current

  for a lower or higher ambient temperature, use a correction factor (typical value) from

  the table below:

  Ambient temperature [°C] Correction factor

  -5 0.87

  0 0.90

  +10 0.95

  +23 1.00

  +30 1.04

  +40 1.10

  +50 1.15

  +60 1.20

  Example: Rated current = 5 A; Environmental temperature = 40 °C; --> Correction factor =

  1.1; Resulting current = 5.5 A --> Fount to next higher rated current: 6 A

  1.0 T11-211-1 4400.0008

  3.0 A T11-211-3 4400.0010

  0.8 A T11-211-0.8 4400.0042

  12.0 A T11-211-12 4400.0052

  1.5 A T11-211-1.5 4400.0056

  0.3 A 0.3

  0.4 A 0.4

  0.5 A 0.5

  0.6 A 0.6

  0.7 A 0.7

  0.8 A 0.8

  0.9 A 0.9

  1.0 1

  1.1 A 1.1

  1.2 A 1.2

  1.3 A 1.3

  1.4 A 1.4

  1.5 A 1.5

  1.6 A 1.6

  1.7 A 1.7

  1.8 A 1.8

  1.9 A 1.9

  2.0 A 2

  2.1 A 2.1

  2.3 A 2.3

  2.5 A 2.5

  2.8 A 2.8

  3.0 A 3

  3.3 A 3.3

  3.5 A 3.5

  4.0 A 4

  4.5 A 4.5

  5.0 A 5

  5.5 A 5.5

  6.0 6

  6.5 A 6.5

  7.0 A 7

  7.5 A 7.5

  8.0 A 8

  8.5 A 8.5

  9.0 A 9

  9.5 A 9.5

  10.0 A 10

  11.0 A 11

  12.0 A 12

  13.0 A 13

  14.0 A 14

  15.0 A 15

  16.0 A 16