厦门晶鼎自动化科技有限公司特价批发德国Schurter全系列产品,欢迎咨询,谢谢!
Thermal (T- and TA-Line)
/PG17_18_19 T11-211
Circuit Breakers
Circuit Breaker for Equipment thermal, Threaded neck type, Reset type, Quick connect terminalsDescription
- Threaded neck type 6 mm
- Thermal circuit breaker
- 1-pole
- Reset type
- Positively trip-free release
- Quick connect terminals 6.3 x 0.8 mm
Standards
- IEC 60934
- UL 1077
- CSA C22.2 235
- GB 17701
Applications
- Power tools
- Household Equipment
- Power supplies and chargers
- Industrial appliances
Weblinks
pdf-datasheet, html-datasheet, General Product Information, Approvals,
CE declaration of conformity, RoHS, CHINA-RoHS, REACH, e-Shop,
SCHURTER-Stock-Check, Distributor-Stock-Check, Detailed request for
product, Product News
Technical Data
Rated Voltage AC 240 V; 50/60 Hz
Rated Voltage DC 48 V
Rated current range AC 0.05 - 16 A
Conditional short circuit capacity
IEC: Inc, PC1, AC 240V: 2kA
Short circuit capacity Icn
at In 1.5 kV
Impulse 1.2/50 μs: > 2.5 kV
Insulation resistance 500 VDC > 100 MΩ
Endurance typical 2 x Ir: 500 switching cycles
Endurance minimum Reset type
AC : 2 x Ir , cos φ 0.6 :
DC : 2 x Ir , L/R = 2 - 3 ms :
50 switching cycles
Overload IEC: min. 40 trips
@ 6 x Ir, cos φ 0.6 UL / CSA: min. 50 trips
@ 1.5 x Ir, cos φ 0.75
Ambient temperature -5 °C to 60 °C
Vibration Resistance ± 1.5 mm @ 10 - 60 Hz
acc. to IEC 60068-2-6, test Fc
5 G @ 60 - 500 Hz
acc. to IEC 60068-2-6, test Fc
Shock Resistance 100 G / 6 ms
acc. to IEC 60068-2-27, test Ea
Tripping Type Therma
Actuation type Reset type
Weight ca. 10 g
Conditional short circuit ca