The advantage of equipment
RAY series of X ray diffraction is the only imported programmable controller technology and modularization design idea into the design of the product, its three without interference isolation protection scheme, make the instrument more superior performance, low failure rate, and prolonging the service life of the complete machine. Design of the precision of its hardware, software, and complete functions, can flexibly adapt to all kinds of material micro structure test, analysis and research. RAY series of X ray diffraction to control its functions, advanced data processing software of perfect and high accuracy of test results, in the domestic leading level of similar instruments.
Technical parameters
X light tube (import)
Target type ceramic tube or metal ceramic tube technology: Cu, Fe, Co, Cr, Mo, Ti, W.
Focus size 1 x 10mm or 0.4 x 14mm
The maximum output power of 2.4kW or 2.7kW
PLC control
X ray generator control method of microcomputer automatic control 1kV/step, 1mA/step import high frequency high voltage control
X ray tube voltage 10~60kV 60kV
X light tube current of 2~80mA 60mA
The maximum output power of 5kW 3kW
The output stability of + 0.005% (power supply voltage fluctuation 10%) + 0.001%
(power supply voltage fluctuation 10%)
Goniometer vertical structure (-2 theta theta) sample level (s- theta theta d)
Goniometer radius of standard 185mm (150mm~285mm adjustable)
The scanning range of -35 DEG to 170 deg.
Scanning speed is 0.06 DEG to 120 DEG /min
The step angle is 0.0001 degrees 0.001 degrees
The accuracy of the measurement is less than or equal to 0.001 DEG
Angle positioning speed 1500 degrees /min (2 0)
The 2 angle is smaller than 0.0005 DEG repeatability precision
Counter
A recording control unit system counter proportional (PC) or flicker (SC) imported detector
The maximum count rate of 1 * 107CPS (<1CPS noise)
The energy resolution is less than or equal to 20% (PC) or less than 50% (SC)
Counter pressure 0 ~ 2100V or 0 ~ 1100V continuously adjustable
Comprehensive index warning device is provided with a kV high, kV is too low, too high, too low mA, mA water, X light pipe over temperature, over-current protection, machine X light tube power protection function
Safety index of protection system for double protection, with the provincial Environmental Protection Bureau issued "radiation safety permit >, to ensure the safety of users.
0.1 sv/h leakage of X ray (X ray tube at maximum power)
The comprehensive stability degree is less than or equal to 0.3%
1170mm dimensions (length) * 870mm (wide) x 1800mm (high)