  Definitions

  本公司长期回收销售:万用表 示波器 网络分析仪 频谱分析仪 信号发生器 LCR测试仪 电桥 电源 综合测试仪 GPIB卡 等世界著名品牌产品。

  高价回收                    二手转让                     销售租凭

  看浓浓的年味儿,说悠悠的年事儿,描红红的年画儿,盼火火的年景儿,品甜甜的年糕儿,吃香香的年饭儿,抱胖胖的年兔儿,读暖暖的年信儿!春节快乐!

  General

  Product data applies under the following conditions:

  · Three hours storage at ambient temperature followed by 15 minutes warm-up operation

  · Specified environmental conditions met

  · Recommended calibration interval adhered to

  · All internal automatic adjustments performed, if applicable

  Specifications with limits

  Represent warranted product performance by means of a range of values for the specified parameter. These specifications are

  marked with limiting symbols such as , ≥, ±, or descriptions such as maximum, limit of, minimum. Compliance is ensured by

  testing or is derived from the design. Test limits are narrowed by guard bands to take into account measurement uncertainties, drift

  and aging, if applicable.

  Specifications without limits

  Represent warranted product performance for the specified parameter. These specifications are not specially marked and represent

  values with no or negligible deviations from the given value (e.g. dimensions or resolution of a setting parameter). Compliance is

  ensured by design.

  Typical data (typ.)

  Characterizes product performance by means of representative information for the given parameter. When marked with or as a

  range, it represents the performance met by approximately 80 % of the instruments at production time. Otherwise, it represents the

  mean value.

  Nominal values (nom.)

  Characterize product performance by means of a representative value for the given parameter (e.g. nominal impedance). In contrast to

  typical data, a statistical evaluation does not take place and the parameter is not tested during production.

  Measured values (meas.)

  Characterize expected product performance by means of measurement results gained from individual samples.

  Uncertainties

  Represent limits of measurement uncertainty for a given measurand. Uncertainty is defined with a coverage factor of 2 and has been

  calculated in line with the rules of the Guide to the Expression of Uncertainty in Measurement (GUM), taking into account

  environmental conditions, aging, wear and tear.

  Device settings and GUI parameters are indicated as follows: “parameter: value”.

  Typical data as well as nominal and measured values are not warranted by Rohde & Schwarz.