您的位置:商铺首页 >> 行业资讯 >> 详情

销售租凭ZNC网络分析仪

时间:2018-03-17 20:54

  销售租凭ZNC网络分析仪二手销售租凭ZNC网络分析仪 R&SZNC 矢量网络分析仪在面向未来的平台上保持可靠性能 频率范围介于 9 kHz 至 3 GHz 

  高价回收          二手转让         销售租凭

  晴天雨天阴天,愿您开心每一天;亲情友情爱情,愿您天天好心情;爱心真心关心,只愿您天天顺心;诚意情意心意,祝您万事如意---春节快乐!

  Definitions

  General

  Product data applies under the following conditions:

  • Three hours storage at ambient temperature followed by 60 minutes warm-up operation

  • Specified environmental conditions met

  • Recommended calibration interval adhered to

  • All internal automatic adjustments performed, if applicable

  • Unless stated otherwise, specifications apply to test ports and a nominal source power of –10 dBm

  Specifications with limits

  Represent warranted product performance by means of a range of values for the specified parameter. These specifications are

  marked with limiting symbols such as , ≥, ±, or descriptions such as maximum, limit of, minimum. Compliance is ensured by

  testing or is derived from the design. Test limits are narrowed by guard bands to take into account measurement uncertainties, drift

  and aging, if applicable.

  Specifications without limits

  Represent warranted product performance for the specified parameter. These specifications are not specially marked and represent

  values with no or negligible deviations from the given value (e.g. dimensions or resolution of a setting parameter). Compliance is

  ensured by design.

  Typical data (typ.)

  Characterize product performance by means of a representative value for the given parameter (e.g. nominal impedance). In contrast to

  typical data, a statistical evaluation does not take place and the parameter is not tested during production.

  Measured values (meas.)

  Characterize expected product performance by means of measurement results gained from individual samples.

  Uncertainties

  Represent limits of measurement uncertainty for a given measurand. Uncertainty is defined with a coverage factor of 2 and has been

  calculated in line with the rules of the Guide to the Expression of Uncertainty in Measurement (GUM), taking into account

  environmental conditions, aging, wear and tear.

  Device settings and GUI parameters are indicated as follows: “parameter: value”.

  Typical data as well as nominal and measured values are not warranted by Rohde & Schwarz. 

  Version 03.02, October 2014

  4 Rohde & Schwarz R&S

  ZNC Vector Network Analyzer

  Measurement range

  Impedance 50 Ω

  Test port connector N female

  Number of test ports 2

  Frequency range R&S

  ZNC3 9 kHz to 3 GHz

  Static frequency accuracy 8 ppm

  Frequency resolution 1 Hz

  Number of measurement points per trace 2 to 5001

  Measurement bandwidth 1/1.5/2/3/5/7 steps 1 Hz to 300 kHz

  Dynamic range 1 9 kHz to 100 kHz > 90 dB, typ. 110 dB

  100 kHz to 1 MHz > 115 dB, typ. 120 dB

  1 MHz to 3 GHz > 120 dB, typ. 130 dB  