环境空气中5种有机硫化物测定专用填充柱

名称:环境空气中5种有机硫化物测定专用填充柱

供应商:浩瀚色谱(山东)应用技术开发有限公司

价格:面议

最小起订量:1/根

地址:山东滕州市(商务部和技术部)

手机:13963221227

联系人:王经理 (请说在中科商务网上看到)

产品编号:216142524

更新时间:2024-06-01

发布者IP:119.186.201.104

详细说明

  浩瀚色谱采用"吸附管采样—热脱附—气相色谱-质谱法"同时测定环境空气中甲硫醇、乙硫醇、甲硫醚、乙硫醚和二甲基二硫醚5种有机硫化物,以样品冷藏保存的条件下,5种有机硫化物的质量浓度分别在5.35×10-3~8.56×10-2,6.93×10-3~1.11×10-1,6.93×10-3~1.11×10-1,1.01×10-2~1.61×10-1,1.01×10-2~1.68×10-1 mg/m3的范围内与峰面积呈良好的线性关系;当采样体积为10 L时,方法检出限为1.13×10-3~2.80×10-3 mg/m3,相对标准偏差为2.76%~7.73%,加标回收率为78.5%~106.0%.对实际样品的测定结果与GB/T 14678—1993方法无显著性差异.

  本方法适用于恶臭污染源排气和环境空气中硫化氢、甲硫醇、甲硫醚和二甲二硫的同时测定。气相色谱仪的火焰光度检测器(GC-FPD)对四种成分的检出限为0.2╳10-3~1.0╳10-3g,当气体样品中四种成分浓度高于1.0mg/m3时,可取1~2mL气体样品直接注入气相色谱仪分析。对1L气体样品进行浓缩,四种成分的方法检出限分别为.2╳10-3~1.0╳10-3mg/m3。

  名称:硫化物测定专用柱

  型号:XY-Sulfur

  规格:3m*2mm(ID)*3mm(OD)

  *高使用温度:120°C

  编号:20240513009

  应用;GB/T 14678-93空气质量 硫化氢、甲硫醇、甲硫醚和二甲二硫的测定 气相色谱法

  适用于安捷伦6890,7890,7820,8860,8890

  Haohan Chromatography uses "adsorption tube sampling thermal desorption gas chromatography-mass spectrometry" to simultaneously determine 5 organic sulfides in ambient air, including methyl mercaptan, ethyl mercaptan, methyl sulfide, ethyl sulfide, and dimethyl disulfide. Under the condition of sample refrigeration, the mass concentrations of the 5 organic sulfides show a good linear relationship with peak area within the range of 5.35 × 10-3 to 8.56 × 10-2, 6.93 × 10-3 to 1.11 × 10-1, 6.93 × 10-3 to 1.11 × 10-1, 1.01 × 10-2 to 1.61 × 10-1 mg/m3, respectively; When the sampling volume is 10 L, the detection limit of the method is 1.13 × 10-3~2.80 × 10-3 mg/m3, the relative standard deviation is 2.76%~7.73%, and the spiked recovery rate is 78.5%~106.0%. There is no significant difference between the actual sample measurement results and the GB/T 14678-1993 method

  This method is applicable for the simultaneous determination of hydrogen sulfide, methyl mercaptan, methyl sulfide, and dimethyl disulfide in the exhaust of odor pollution sources and ambient air. The detection limit of the flame photometric detector (GC-FPD) of the gas chromatograph for the four components is 0.2 × 10-3~1.0 × 10-3g. When the concentration of the four components in the gas sample is higher than 1.0mg/m3, 1-2mL of gas sample can be directly injected into the gas chromatograph for analysis. Concentrate 1L of gas sample, and the detection limits for the four components are. 2 × 10-3~1.0 × 10-3mg/m3, respectively.

  Name: Special column for sulfide determination

  Model: XY-Sulfur

  Specifications: 3m * 2mm (ID) * 3mm (OD)

  *High operating temperature: 120 ° C

  Number: 20240513009

  Application; GB/T 14678-93 Air Quality - Determination of Hydrogen Sulfide, Methylthiol, Methyl Sulfide and Dimethyl Disulfide - Gas Chromatography Method

  Applicable to Agilent 68907890782088608890