详细说明
浩瀚色谱(山东)应用技术开发有限公司,采用气相色谱法测定环氧丙烷中乙醛、丙醛的质量分数,测定结果的相对标准偏差均小于10%,方法的回收率范围为(100±5)%,检测限低至1×10-6,证明该方法能快速、简便、准确地测定环氧丙烷中乙醛、丙醛的含量。
名称:毛细管柱
型号:二乙烯基苯--乙二醇--二甲基丙烯酸
规格:30M*0.32MM*7UM
zui高使用温度:250°C
编号:20240406006
应用:
岛津GC2014,GC-2010,GC-2018,GC-2030;安捷伦6890,7890,7820,8860,8890;赛默飞,瓦里安
Haohan Chromatography (Shandong) Application Technology Development Co., Ltd. used gas chromatography to determine the mass fractions of acetaldehyde and propanal in epoxy propane. The relative standard deviation of the measurement results was less than 10%, and the recovery range of the method was (100 ± 5)%. The detection limit was as low as 1 × 10-6, proving that the method can quickly, conveniently, and accurately determine the content of acetaldehyde and propanal in epoxy propane.
Name: Capillary Column
Model: divinylbenzene ethylene glycol dimethylacrylic acid
Specification: 30M * 0.32MM * 7UM
Zui high operating temperature: 250 ° C
Number: 20240406006
Application:
Shimadzu GC2014, GC-2010, GC-2018, GC-2030; Agilent 68907890782088608890; Thermo Fisher, Varian