福鼎 FDS-2209040R8w跑赛道扬声器喇叭

名称:福鼎 FDS-2209040R8w跑赛道扬声器喇叭

供应商:江阴市福鼎通讯器材有限公司

价格:面议

最小起订量:1000/个

地址:江苏省无锡市江阴月城镇月冯路29号

手机:13861148699

联系人:陈红波 (请说在中科商务网上看到)

产品编号:149058304

更新时间:2021-04-14

发布者IP:183.210.202.244

详细说明

  产品描述(超薄喇叭)

  产品名称:FDS-2209040R8w

  尺寸:22x9mm

  额定功率:0.5 W

  最大功率:1.0W

  阻抗:8±15% Ω

  重量:1.5g

  共振频率:20KHz

  灵敏度/声压:87± 3 dB

  谐振频率:600±20%Hz

  频响曲线: As shown in fig(2)

  1.SPECIFICATIONHDK-220908ZA-1W1 (RoHS)

ITEMSPECIFICATIONS
01TypeDynamic speaker
02DimensionExternal diameter 22*9mm
03Rated Input Power0.5W(Long Time)
04Max. Input Power1.0W (Short Time)
05Impedance8ohm ± 15% at1500Hz.
06Resonance Frequency (Fo)900Hz ± 20% at Fo, 1V
07Sensitivity (S.P.L.)87dB(0.1W/0.1m) ± 3 dB at AVE1.2–2.5KHz.
90dB (0.5W /0.1m) ± 3 dB
08Frequency RangeFo – 20KHz
09Total Harmonics Distortion Max8% at 1KHz,0.5W.
10Voice CoilDiameter11*4mm
11MagnetRare earth permanent (Nd-Fe-B) magnet Φ10.4*3.45*1.2mm
12Weight2.0g ± 5%g
13AppearanceShould not exist any obstacle to be harmful to normal operation; damages, cracks, rusts and distortions, etc.
14Operation TestMust be normal at program source –0.5W
15Buzz, Rattle, etc.Should not be audible at 2.0V sine Wave between Fo to20KHz
16PolarityWhen positive voltage is applied to the terminal marked (+), diaphragm should move to the front.
17Terminal StrengthCapable of withstand 1kg load for 30 seconds without resulting in any damage or rejection.
18TemperatureOperating temperature: -20℃to +60℃Storage temperature: -30℃to +70℃

  1.MEASURING METHOD

  2-1 .Test Condition

  STANDARD

  Temperature : 15 ~ 35℃

  Relative humidity : 45% ~ 85%,

  Atmospheric pressure : 860mbar to 1060mbar.

  JUDGEMENT

  Temperature : 20±3℃

  Relative humidity : 60% ~ 70%,

  Atmospheric pressure : 860mbar to 1060mbar

  2-2 .Standard Test Fixture

  1.Input Power : 0.8W (2.53V )

  2.Zero Level : -dB

  3.Mode : SPEAKER

  4.potentiometer Range : 50dB

  5.Sweep Time : 0.5sec

  2-3. Frequency Response Curve

  2.RELIABLITY TESTS

Items.Specifications
01High temp. TestKeep 96 hours at +70℃±3℃and leave 3 hours in normal temperature and then check
02Low temp. TestKeep 96 hours at -30℃±3℃and leave 3 hours in normal temperature and then check
03Humidity testKeep 96 hours at + 60℃±3℃relative humidity 95% and leave 3 hours in normal temperature and then checked.
04Temp./Humidity cycleThe part shall be subjected 5cycles. One cycle shall be 12hours and consist of;
05Thermal cycle test.Low temperature: -30℃±3℃, temperature:+70℃±3℃, cycle: 1 hour/cycle each, and then keep 5cycles in a room.
06Vibration10~200~10Hz sin-wave sweep 15min. 5G(constant)X,Y, Z3 direction. 2 hours each, total 6 hours.
07Fix drop testFix on jig. Then drop from 152cm height to the concrete floor X,y, z 6 direction. 5 times each, total 30 times.
08Freedrop testFree drop from 100cm height to the concrete floor X,y, z 6 direction. 1times each, total 6times.
09Rated Powertest Rated Power white noise is applied for 96 hours
10Max Power testMax power 1 min on –2min off 10 cycles.
11Terminal strength testCapable of withstand 1kg load for 30 seconds without resulting in any damage or rejection.
Criterion:After these test , the change of S.P.Lshall be within ±3 dB.