Current Range : 0.1 A…30 A peak1 A…300 A peak1 A…2000 A peakSignal de sortie : 100 mV AC/A AC (1 V to 10A)10 mV AC/A AC (1 V to 100A)1 mV AC/A AC (1 V to 1000A)Frequency range : 10 Hz…100kHz(-3dB)dl/dt max. : 10 A/µsCurrents maxima : 1000 A continuous for a frequency ≦ 1kHz
(limitation proportional to the opposite of frequency beyond)1200 A for 40 min max.
( pause between measurement > 20 min)Load impedance : ≧1MΩ and ≦ 47 pFOutput impedance 1kHz : 515Ω ± 10%Accuracy and phase shift : Range 10 A :
Primary current | 0.1…0.5A | 0.1…2A | 2…10A | 10…12A |
Accuracy in % of output signal | ≦ 3% + 10 mV | ≦ 3% + 10 mV | ≦ 3% + 10 mV | ≦ 3% + 10 mV |
Phase shift | not specified | not specified | ≦ 15∘ | ≦ 15∘ |
Range 100A :
Primary current | 0.1…0.5A | 5…20A | 20…100A | 100…120A |
Accuracy in % of output signal | ≦ 2% + 5 mV | ≦ 2% + 5 mV | ≦ 2% + 5 mV | ≦ 2% + 5 mV |
Phase shift | not specified | ≦ 15∘ | ≦ 10∘ | ≦ 5∘ |
Range 1000A :
Primary current | 1…50A | 50…200A | 200…1000A | 1000…1200A |
Accuracy in % of output signal | ≦ 1% + 1mV | ≦ 1% + 1mV | ≦ 1% + 1 mV | ≦ 1% + 1 mV |
Phase shift | not specified | ≦ 3∘ | ≦ 2∘ | ≦ 1∘ |
Insertion impedance (at 50/60 Hz) : Range 10 A: < 10 mΩRange 100 A: < 10 mΩRange 1000 A: < 100 mΩAmpere product x second : 1 A.sRising time/ Falling down time : ≦ 40 µsWorking voltage : 600 V rmsCommon mode voltage : 600 V for category III and pollution level 2Adjacent conductor influence : ≦ 1mA to 50 HzInfluence of conductor influence in the jaws : ≦ 0.1% of output signal for frequencies ≦ 400 HzFrequency influence : Range 10 A< 10% of output signal 10 Hz…1 kHz< 5% of output signal 1 kHz…10 kHz< 20% of output signal 10 kHz.....50 kHz< 3 dB 50 kHz…100 kHzRange 100 A< 5% of output signal 10 Hz…1 kHz< 3% of output signal 1 kHz…10 kHz< 20% of output signal 10 kHz…50 kHz< 3 dB 50 kHz…100 kHzRange 1000 A]< 1% of output signal 10 Hz…1 kHz < 2% of output signal 1 kHz…10 kHz < 10% of output signal 10 kHz…50 kHz < 3 dB 50 kHz…100 kHz Influence of crest factor : <1 % of output signal for a crest factor ≦ 6 with current Range 10 A: ≦ 30 A peak(5 A rms) Range 100 A: ≦ 300 A peak(50 A rms) Range 1000 A: ≦ 2000 A peak(500 A rms) Influence of DC current
superposed to nominal current : <1 % of output signal for a current≦ 30A DC