SCU-100日本PMT变送器

名称:SCU-100日本PMT变送器

供应商:深圳市华兴瑞科技有限公司

价格:面议

最小起订量:1/台

地址:深圳市龙岗区布吉美杜兰华庭

手机:13632880520

联系人:陈工 (请说在中科商务网上看到)

产品编号:71002500

更新时间:2021-01-23

发布者IP:121.35.102.120

详细说明

  SCU-100日本PMT变送器 日本positive contac株式会社 原装进口产地:日本岐阜市大川  

  深圳市华兴瑞日本PMT工具破碎检出系统(断刀检测器)、传感器及气缸

  深圳市华兴瑞科技有限公司

  日本positive contac 产地:日本岐阜市大川  

  工具破碎检出装置PCS-100

  传感器PCS-100及针组件

  控制元件SCU-100A

  连接电缆(标长5米)及w/L90 接头

  工具破碎检出装置PCS-250

  传感器PCS-250及针组件 

  控制元件TCU-250A

  连接电缆(标长5米)及w/L90 接头

  SCU Terminal Descriptions

  Terminals 1 & 2: The SCU operates with 24VDC, note that terminal 1 is + and

  terminal 2 is - . This unit requires a minimum supply of 250 mA. When powering the

  SCU with an existing 24VDC power supply, confirm that the supply is capable of

  additional output capacity to power the SCU.

  Terminals 3 & 4: Not used.

  Terminals 5, 6, 7 & 8: Sensor cable connection, as indicated. The preferred method

  is to connect the cable directly from the sensor to the SCU. If the SCU and sensor

  need to be connected via external junction box, avoid wiring near electromagnetic

  or high current devices. DO NOT connect the braided shield in the

  supplied sensor cable to the machine ground !

  Terminals 9 & 10: are dry contacts ( internal relay )

  capable of switching 2A @ 250 VAC. The contact

  operation can be configured eliminating peripheral

  devices for interfacing theSCU-100日本PMT变送器 ( see Relay Control

  Switches, page 7 )

  Terminal 13: Is used to reset the SCU after a fault

  condition has been detected. The required input is

  + 24VDC for a minimum of 100mS. (OPTIONAL)

  Terminals 14, 15 & 16 are used to activate the

  checking sequence when required in your

  application. T-16 is the common for either a 115VAC

  start signal (T-14 ) or a 24VDC start signal ( T-15 ).

  The SCU recognizes a change of state in the circuit

  to activate the checking sequence. A minimum

  duration of 100mS is required regardless of the of

  the signal utilized, ( HI – LO – HI ) or ( LO – HI – LO ).

  SCU-100

  9 10 11 12 13 14 15 16

  Certain solid state devices, although in their off ( LO ) state, may output a small

  amount of current. Depending on the operating characteristics of these devices, the

  SCU may not recognize a change of state. If this condition occurs in your application

  you may need to incorporate an external relay to activate the checking sequence.

  Terminals 11 & 12: are dry SCU-100日本PMT变送器contacts ( internal relay ) capable

  of switching 2A @ 250 VAC. The contact operation can be

  configured eliminating peripheral devices for interfacing the

  SCU. ( see Relay Control Switches, page 7 )

  The Start Signal can also be used as a RESET function. After the error

  condition has been corrected, (replace broken tool), applying a Start Signal

  will cause the sensor to begin the checking sequence; touching and confirming

  that the tool has been replaced, in-turn resetting the Control Unit.

  Page 6SCU-100日本PMT变送器

  OK LED (See Relay Control Switches Below)

  The OK LED will illuminate at power on. When a start signal is initiated

  the LED will momentarily turn off. If a good condition has been

  detected the LED will again illuminate momentarily.

  FAULT LED (See Relay Control Switches Below)

  When a fault or broken tool condition is detected the FAULT LED will

  illuminate momentarily or until the unit is reset if relay is set to Latch.

  CW / CCW Switch

  This switch selects the rotation of the sensor. This setting MUST

  correspond with the knurled adjustment on the sensor.

  LO / HI SwitchSCU-100日本PMT变送器

  Selects the rate at which the sensor swings. “HI is the correct setting

  for nearly all applications. “LO” rate is a slower swing rate generally

  used only for micro tool detection. NOTE: The V-seal in the swing arm

  assembly provides additional protection against contaminants and

  should not be removed in most applications. The V-seal may however

  restrict the sensors motion when the swing rate is set on “LO”. If your

  application does not allow “HI” rate operation, you may remove the Vseal

  from the swing arm assembly to determine if this solves the

  problem.SCU-100日本PMT变送器

  Time Switches

  These switches control the amount of time the sensor rotates during

  the scanning sequence. Since it takes a greater amount of time to

  swing the sensing needle 180º than 90º, a greater amount of time

  主要型号:PCS-100、PCS-250、SCU-100、TCU-250