1.All materials are UL 94VO grade,high temperature resistance plastic
2.Twin contact design to ensure stable contact.
3.Gold-plated contact to ensure low contact resistance.Tin plated terminals to prevent contamination during soldering.
Ratings:
Contact Rating
Switching :25mA at 24VDC
Non-Switching :100mA at 50VDC
Contact Resistance
Initial : 50MΩMax
After life :100MΩMax
Insulation Resistance:100MΩMin,60sec at 500VDC
Dielectric Strength:500VDC for 60 seconds
Switch Capacitance:5pF Max at 1 MHZ
Operation Temperature:-40℃~+85℃
Storage Temperature:-40℃~+85℃
Mechanical&Processing
Operation Force:1000gfMax
Mechanical Life :3000 cycles Operations
Switch Operation and Taping
1.Use Tweezer or ball point pen for operation
2.Flux cleaning should be done without removing the Tape.
3.If the Tape is removed,it adhered less than before when it is placed back on ,possibl causing flux inflow.
4.Do Not Remove Tape sealed before Reflow Processing.
5.Ultasonic cleaning not recommended without Tape sealesd
*Keep all actuators in “OFF”position during soldering and cleaning process.
*Any flux enters the switch may influence contact function.
Environmental TEST
Cold Resistance Test
Switches under temperature at - 40℃ ±2℃ for 96 hours
Dry Heat Resistance Test
Switches under temperature at 85℃ ±2℃for 96 hours.
Humidity Test
Per MIL-STD- 202F,Method 103B Test Condition B:
There shall be no evidence of corrosion and the insulation resistance shall be no less than 100 megaohms
Vibration Test:
Per MI-STD- 202F,Method204 D,Test Condition A:
There shall be no opening of closed contacts or closing of open contacts in excess of 10 microseconds.
Shock Test:
Per MIL-STD- 202F,Method 213B ,Test Condition A:
There shall be no opening of closed contacts or closing of open contacts in excess of 10 microsecond.
Thermal Shock Test:
Per MIL-STD- 202F,Method 107G,Test Condition A:
There shall be no evidence of physical damage or permanent change in electrical characteristics .
Salt-Spray Test
Per MIL -STD - 202 F,Method 101D,Test Condition B :
There are under 35℃ ±2℃ in temperature and 5±1% salt-water concentration for 48±1 hour.